What was found
ACCOMPLISH IDENTIFICATION OF EXISTING STRINGER SPLICE REPAIR AT STA 600 STR 28L. EXISTING REPAIR FOUND TO BE NON COMPLIANT IAW 727 SRM 53-10-3 FIG 1 TABLE I. REMOVED EXISTING REPAIR IAW 727 SRM 51-30-2 FABBED AND INSTALLED NEW STR SECTIONS 2EA FROM BAC1498-141 PO 427415 DIM 19"EA AND 3 EA SPLICE SECTIONS FROM BAC1498-132 PO5400126 DIM 13" EA IAW B727 SRM 53-10-3 FIG 1.