As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT CARGO PIT CORROSION ON FLOOR SUPPORT CHANNEL, LWR SIDE, BETWEEN STA 1030 AND 1050 RBL 8. REMOVED SECTION OF FLOOR SUPPORT. FABRICATED AND INSTALLED (3) REPAIR SPLICES 10.50" BY 1" FROM BAC1490-2583, 10.50 BY .085" BY .085" FROM AND10133-0702 AND 29" BY .090" BY 1" BY .050" IAW B727 SRM 53-10-5 FIG 4.