What was found
FOUND FWD PIT STRINGER CRACKED STA 675 S-29L. CUT OUT CRACKED SECTION OF STRINGER AT STA 675 STR 29L. FABRICATED AND INSTALLED REPAIR STRINGER SECTION 20-5/8" FROM BAC1498-132 AND 5" FROM BAC1498-144 IAW B727 SRM 53-10-3 FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND FWD PIT STRINGER CRACKED STA 675 S-29L. CUT OUT CRACKED SECTION OF STRINGER AT STA 675 STR 29L. FABRICATED AND INSTALLED REPAIR STRINGER SECTION 20-5/8" FROM BAC1498-132 AND 5" FROM BAC1498-144 IAW B727 SRM 53-10-3 FIG 1.