As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FOUND FWD PIT FLOOR SUPPORT HAS CORROSION AROUND FASTENER HOLES LWR SIDE STA 644 LBL 2. CUT OUT CRACKED SECTION OF FLOOR SUPPORT STA 644 LBL 2. FABRICATED AND INSTALLED REPAIR SPLICES 18-1/2" BY 1" BY 1-1/4" FROM BAC1520-1485 AND 8-1/2" BY 5/8" BY 1" BAC1509-100146 AND 8-1/2" BY 1" BY 1-3/8" FROM BAC1490-2734 IAW B727 SRM 53-10-5 FIG 4.