What was found
AFT CARGO COMPT BILGE, BS 1010 FRAME CORRODED AT LOWER FWD SIDE BETWEEN STR 29R - 30. CUT OUT CORRODED AREA. FABRICATED AND INSTALLED REPAIR 5.25" BY 5.25" BY 3.75" BY .75" FROM 7075-T6 .071 IAW B727 SRM 53-10-4 FIG 13.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO COMPT BILGE, BS 1010 FRAME CORRODED AT LOWER FWD SIDE BETWEEN STR 29R - 30. CUT OUT CORRODED AREA. FABRICATED AND INSTALLED REPAIR 5.25" BY 5.25" BY 3.75" BY .75" FROM 7075-T6 .071 IAW B727 SRM 53-10-4 FIG 13.