What was found
DURING A "C" CHECK, AFT CARGO CORROSION ON INTERCOSTAL STA 1150 TO 1166 O/B OF 26R. EVALUATED ANGLE FROM BS 1150 TO 1166 AND FOUND IT TO BE OUT OF LIMITS IAW 727 SRM 53-10-1 FIG 5. REMOVED ANGLE FROM BS 1150 TO 1166 IAW 727 SRM 51-30-2. FABRICATED ANGLE FROM 7075 T6 .050 PO NR 9001777 14 1/8 INCH BY 2 INCH IAW 727 SRM 53-10-2 FIG 5 AND 51-20-1. TREATED AND PRIMED ANGLE AND BARE METAL IAW 727 SRM 51-10-2. INSTALLED ANGLE IAW 727 SRM 51-30-2.