What was found
DURING A "C" CHECK, AFT CARGO DENT FRAME STA 1110 AT STA 23 LT. REMOVED FASTENERS FOR ACCESS AT AFT CARGO STA 1110 AT STA 23 LT IAW B727 SRM 51-30-2. CUT OUT DAMAGE AREA DIMENSION 2 INCH BY 1 INCH IAW B727 SRM 51-40-3 FIG 1. FABRICATED FRAME REPAIR MAT USED 7075-T6 .071 PO NR 900573 DIMENSION 18 INCH BY 5 1/4 INCH IAW B727 SRM 53-10-2 FIG 5 AND 51-40-3 FIG 1. ALODINED AND PRIMED AREA AND PART IAW B727 SRM 51-10-2. INSTALLED FRAME REPAIR IAW B727 SRM 51-40-3 FIG 1.