What was found
DURING A "C" CHECK, FRAME DENTED AT S25L BS950F. REMOVED FASTENER FOR ACCESS AT STA S25L BS950F IAW B727 SRM 51-30-2. CUT OUT DAMAGE AREA DIM 1.5 INCH BY 1 INCH IAW B727 SRM 51-40-3 FIG1. FABRICATED FRAME REPAIR MAT USED 7075T6 .071 PO NR 900573 DIM 9 3/4 INCH BY 4 .25 INCH IAW B727 SRM 53-10-2 FIG 5 AND 51-40-3 FIG 1. ALODINED AND PRIMED PART IAW B727 SRM 51-10-2. INSTALLED FRAME REPAIR IAW B727 SRM 51-40-3 FIG 1.