What was found
DURING A C-CHECK, PREVIOUS REPAIR ON LOWER TORQUE BOX LIGHTENING HOLE IMPROPERLY DONE R/SIDE AT FWD STA 1243. REMOVED PREVIOUS REPAIR ON LOWER TORQUE BOX LIGHTENING HOLE R/SIDE AT FWD STA 1243 IAW B727 SRM B727 SRM 51-30-2. STOP DRILL CRACK 250 TERIMINATED AT END OF CRACK IAW B727 SRM 51-10-1. ACCOMPLISHED 727 HFEC INSPECTION 51-00-00 FIG 4 END OF CRACK IAW B727. FABRICATED DOUBLER REPAIR MAT IDENTIFICATION 53-10-2 FIG 6, FROM MAT 7075T6 .040 DIM 4 X 4.625 INCH PO9001068 IAW B727 SRM 51-40-2 FIG 1. ALODINED AND PRIMED IAW B727 SRM 51-10-2, INSTALLED DOUBLER REPAIR IAW B727 SRM 51-40-2 FIG 1.