What was found
DURING A C-CHECK, AFT PIT FRAME DENTED BS 1130 STR 26 RT. CUT OUT DAMAGED AREA FROM FRAME BS 1130 STR 26 RT IAW 727 SRM 53-10-1 FIG 1. FABRICATED DOUBLER FROM 7075-T6 .063 PO NR 9001660 8.5 X 3 INCHES & STRIP FROM 7075T6 .063 PO NR 9001660 8.5 X 1 INCHES AND FILLER FROM 7075T6 .063 PO NR 9001660 1.25 X 1 INCHES IAW 727 SRM 53-10-3 FIG 1 AND 51-40-3 FIG 1. TREATED AND PRIMED PARTS AND BARE METAL IAW 727 SRM 51-10-2. INSTALLED DOUBLER IAW 727 SRM 53-10-1.