What was found
BULGE L/SIDE FUSELAGE SKIN AFT OF STA 580 BELOW STR 24L. DAMAGE FOUND TO BE OUT OF LIMITS IAW B727 SRM 53-30-1 FIG 1. CUT OUT DAMAGE AREA FABBED FILLER FROM 2024 T3 .050 PO NR 9001684 DIM 1 1/2 INCH BY 1 1/2 INCH AND DOUBLER FROM 2024 T3 .063 PO NR 9001634 DIM 7 1/2 BY 6 1/2 IAW B727 SRM 53-30-2 FIG 2 53-30-3 FIG 2. TREATED AND PRIMED PARTS IAW B727 SRM 51-10-2. INSTALLED REPAIR IAW B727 SRM 53-30-3 PG2.