What was found
BULGE UNDERNEATH FUSELAGE SKIN FWD OF STA 1050 STR 29R. DAMAGE FOUND TO BE OUT OF LIMITS IAW 727 SRM 53-30-1 FIG 1. CUT OUT DAMAGED AREAS DIM 3 3/4 INCH BY 1 7/8 INCH AT BS 1040 STR 29R AND 3 1/8 INCH BY 3 3/4 INCH ATBS 1040 STR 29L. FABBED 2 FILLERS FROM 2024T3 .071 PO NR 9001978 DIM 3 1/2 INCH BY 1 INCH AND 3 3/4 INCH BY 1 INCH AND DOUBLER FROM 2024T3 .080PO NR 9002012 DIM 21 5/8 INCH BY 18 3/4 INCH IAW 727 SRM 53-30-3 FIG3 AND 53-30-2 FIG2. REPAIR PARTS TREATED, PRIMED AND INSTALLED IAW 727 SRM 51-10-2 AND 53-30-3 FIG 3.