What was found
NR 2 SLAT EXTERNAL SKIN DENTED (3) PLACES. MEASURED DENT AT WS 656.3 ON NR 2 SLAT AND FOUND IN LIMITS A.2/Y.005=40 IAW SRM 53-30-1 FIG 1. MEASURED DENT AT WS 684.3 ON NR 2 SLAT AND FOUND TO BE OUT OF LIMITS A.4/Y.32=28.1 IAW B727 SRM 53-30-1 FIG 1 AND REPAIRED ON NR 82240. MEASURED DENT AT WS 661.3 ON NR 2 SLAT AND FOUND TO BE OUT OF LIMITS A.6/Y.028=21.4 IAW B727 SRM 53-30-1 FIG1. CUT OUT DAMAGED AREA AT WS 661.3 ON NR 2 SLAT SIZE 1 INCH BY 3/4 INCH IAW B727 SRM 57-50-3. FABBED NEW DOUBLER USING 2024T3 .080 PO#9002012 SIZE 4 1/2 INCH BY 4 1/2 INCH IAW B727 SRM 57-50-3 FIG 1. TREATED AND PRIMED IAW B727 SRM 51-10-2. INSTALLED DOUBLER IAW B727 SRM 57-50-3.