What was found
DENT ON NR 8 SLAT EXTERNAL SKIN (MARKED). CUT OUT DAMAGE AREA SIZE 1 INCH BY 1 1/2 INCH IAW B727 SRM 57-50-1 FIG 2. FABRICATED DOUBLER REPAIR USING 2024 T3 .080 PO NR 90020125126 DIMENSIONS 6" BY 5" IAW B727 SRM 57-50-2 FIG 2 AND 57-50-3 FIG 1. ALODINE AND PRIMED PART AND AREA IAW B727 SRM 51-10-2. INSTALLED DOUBLER REPAIR IAW B727 SRM 57-50-2 FIG 2 AND 57-50-3 FIG 1.