What was found
FRAME BETWEEN STR 25-26 R AT STA 1050 BENT. CUT OUT DAMAGE AREA SIZE 1 1/2 INCH BY 1 INCH IAW B727 SRM 53-10-1. FABRICATED FRAME REPAIR USING 7075-T6 .071 PO NR 9002012 DIM 8 INCH BY 4 INCH IAW B727 SRM 53-10-2 FIG 5 AND 51-40-3 FIG 1. ALODINE AND PRIMED PART AND AREA IAW B727 SRM 51-10-2. INSTALLED FRAME REPAIR IAW B727 SRM 53-10-2 FIG 5 AND 51-40-3.