As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FRAME AT STR 26 R STA 1110 BENT. CUT OUT DAMAGE AREA IAW B727 SRM 53-10-1 SIZE 2" BY 1". FABRICATED FRAME DOUBLER USING 7075 T6 .071 PO NR 9001298 DIM 10" BY 4" IAW B727 SRM 53-10-2 FIG 5 AND 51-40-3 FIG 1. ALODINE AND PRIMED IAW B727 SRM 51-10-2. INSTALLED FRAME REPAIR IAW B727 SRM 51-30-2 AND 51-40-3 FIG 1.