What was found
ACCOMPLISH IDENTIFICATION OF EXISTING REPAIR ON FUSELAGE SKIN AT A/C STA 406 STRINGER 24R PER ASTAR J/C NR FCD500001-001B. EXISTING REPAIR FOUND TO BE NON-COMPLIANCE IAW 727 SRM 53-30-3 FIG 1. REMOVED PREVIOUS REPAIR IAW 727 SRM 51-30-2. FABRICATED NEW DOUBLER FROM 2024 T3 .050 PO NR 9002012 DIM 10 7/16" BY 8 1/4" IAW 727 SRM 53-30-2 FIG 1 AND 53-30-3 FIG 1. TREATED AND PRIMED IAW 727 SRM 51-10-2. INSTALLED REPAIR DOUBLER IAW 727 SRM 51-30-2.