What was found
DURING AN A-CHECK, THE FOLLOWING DISCREPANCES WERE NOTED LWR VERTICAL PNL LT SIDE HAS 2 EA DENTS. CUT OUT DAMAGED AREAS APPROX 1 INCH ROUND AND 2 INCHES ROUND IAW B727 SRM 51-40-2 FIG 30, FABRICATED ONE FILLER 1 INCH ROUND AND ONE FILLER 2 INCHES ROUND AND ONE DOUBLER 4 INCHES ROUND AND ONE DOUBLER 5 INCHES ROUND, USING 2024-T3 .016 PO 9001660 IAW B727 SRM 55-30-2 FIG 1. CLEANED, PREPPED, AND APPLIED PRIMER AND ADHESIVE TO ALL REPAIR SURFACES AND BAGGED FOR BONDING IAW B727 SRM 51-40-2 FIG 30. CURED REPAIR, CLEANED AND PERFORMED POST-BOND INSP WITH NO DEFECTS NOTED IAW B727 SRM 51-40-2 PARA 0. TREATED SEALED AND PRIMED REPAIR IAW B727 SRM 51-40-2 PARAGRAPH-P.