What was found
NR 2 ENGINE FIRE WARNING, THE CREW BLEW BOTH FIRE BOTTLES. AFTER STARTING ENG DURING PUSHBACK--HAD ENG NR 2 FIRE WARNING.COMPLETED EMER. CHECK LIST. FIRED BOTH BOTTLES--FIRE WARNING LIGHT AND BELL CONTINUED TO ACTUATE AFTER SHUTDOWN. R/R NR 2 ENG RT CORE FIRE DET. LOOP ASSY PER DC-8 M/M 26-10-1 NO HELP.T/S DOWN TO CONN. P1-7007 (NR 2 ENG LT CORE TO PYLON CONN) R/R CONN. PER DC-8 MM 20-50-1. RAN ENG PER JRH 12.2 OPS CHECKS SERVICABLE.