What was found
WING CTR SECTION FLOORBEAM HOLES (2EA) MISDRILLED, STA 834.500 RBL 32" RBL 37.750 (MAIN CARGO COMPT.) PERFORMED MAJOR REPAIR IAW FAA FORM 8110-3 DATE 11-28-05, DWG NR AA33-53-R06 REV IR DATE 11-16-05. REMOVED FASTENERS IAW SRM 51-1-21. TRIMMED OUT DAMAGED SECTION, FABRICATED REPAIR ANGLE (7075T6 511 0.140") AND (2EA) FILLERS (7075T6 511 0.140") IAW DWG NR AA33-53-R06. CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS IAW SRM 51-1-8B. APPLIED SEALANT TO FAYING SURFACES IAW SRM 51-1-11 PAGE 9. INSTALLED REPAIR PARTS IAW DWG AA33-53-R06, SRM 51-1-20D, SRM 51-3-1.