What was found
FWD CARGO COMPT ZEE FITTING CRACKED 0.500 IN STA 300.000 L-27L. REMOVED CRACKED ZEE FITTING IAW SRM 53-1-0 PG. 1, SRM 51-1-20D. FABRICATED 2EA REPAIR ANGLES IAW SRM 53-2-0 FIG 2D SHEET 1,2, SRM 51-1-4 PG. 1 (FORMING). CUT NEW ZEE FITTING IN HALF USING TRIM DIMENSIONS NOTED IN THE SRM CHAPTER 53-2-0 FIG. 2D SHEET 2. HEAT TREATED REPAIR ANGLES IAW SRM 51-1-1 PG. 1,13,17. CLEANED, TREATED AND PRIMED AREA AND REPAIR ANGLES IAW SRM 51-1-8B. APPLIED SEALANT TO FAYING SURFACES IAW SRM 51-1-11 PG. 9. INSTALLED NEW ZEE FITTING AND REPAIR ANGLES IAW SRM 53-2-0 FIG. 2D SHEET 1,2, SRM 51-1-20D, SRM 51-3-1 (TORQUE).