What was found
MAIN CARGO COMPT FLOORBEAM MISDRILLED HOLE AT STA 879.000 RBL 32 AND SHOWS CORROSION ON FLANGE. PERFORMED MAJOR REPAIR IAW SRM 51-2-1 FIG 1 SHEET 7-12 TR NR 51-130. REMOVED CORROSION IAW SRM 51-1-8 PG 17-18. OUT OF LIMITS IAW SRM 53-2-0 PG 2P. CUT OUT DAMAGED SECTION IAW SRM 51-2-1 FIG 1 SHEET 7. PERFORMED NDT INSP IAW DC8 NDT SPM PART 06-10-01-001. FABRICATED REPAIR ANGLE AND FILLER IAW SRM 51-2-1 FIG 1 SHEET 7-12. HEAT TREATED REPAIR ANGLE IAW SRM 51-1-1 PG 1, 13, 17 DPS 7.00-1 REV BK. CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS IAW SRM 51-1-8B. APPLIED SEALANT IAW SRM 51-1-11 PG 9. INSTALLED REPAIR PARTS IAW SRM 51-2-1 FIG 1 SHEET 7-12, SRM 51-1-21 PG 1, SRM 51-1-20D PG 9. TORQUED IAW SRM 51