What was found
AFT ACCY COMPT FRAME FITTING 1.000 CRACK (STA 660.000-670.000, L-35R TO L-36). PERFORMED MAJOR REPAIR IAW SRM 53-1-0 PG 1. REMOVED CRACKED FITTING IAW SRM 51-1-20D PG 21. CLEANED, TREATED AND PRIMED AREA IAW SRM 51-1-8B. INSTALLED NEW FITTING (PN 3750497U2) IAW SRM 51-1-20D PG 9, SRM 51-3-0 PG 1, SRM 51-1-11. TORQUED IAW SRM 51-3-1.