What was found
AFT ACCY COMPT FRAME FITTING 1.000 CRACK APRROX STA 660.000-670.000, L-35 TO L-36L. PERFORMED MAJOR REPAIR IAW SRM 53-1-0 JC EA53100129-001-D, EA05918, DWG 3750497. REMOVED CRACKED FITTING IAW SRM 51-1-20D PG 21. FABRICATED NEW FITTING IAW EA05918, DWG 3750497. PERFORMED NDT INSP IAW NDT SPM PART 08-00-02 TO 07. APPLIED SEALANT TO FAYING SURFACES IAW SRM 51-1-11 PG 9. INSTALLED NEW FITTING IAW SRM 51-1-20D PG 21, SRM 51-1-21 PG.1, SRM 51-3-0 PG 1. TORQUED IAW SRM 51-3-1.