What was found
E/E COMPT FLOOR AREA BETWEEN FS 17 AND FS 18 AND BETWEEN STR 52L AND STR 54L FLOOR SKIN AND FRAME ANGLE AND STRINGER HAS CORROSION. COMPLIED WITH FSI REPAIR DISPOSITION MSN085/01. FOUND TO BE WITHIN LIMITS, REFER TO ATTACHED 8110-3 DATED NOV 17,2006 (FAA PROJECT NR SP4780SE-Q). THIS IS LIMITED REPAIR FOR 12 MONTHS PENDING DAMAGE TOLERANCE ASSESSMENT.