What was found
FOUND FRAME DENTED AT BS 720A STR 25R. CUT OUT DAMAGED AREA SIZE 1 BY 1 ON FRAME STA 720A AT STR 25R IAW B727 SRM 51-10-1. FABBED REPAIR ANGLE FROM 7075-0 .063 SIZE 8 3/4 BY 3 1/2 PO 9002827 IAW B727 SRM 51-40-3 FIG 1 AND SRM 53-10-2 FIG 3. HEAT TREATED TO 7075-T6 .063, TREATED AND PRIMED PART AND AREA IAW B727 SRM 51-10-2. INSTALLED REPAIR ANGLE IAW B727 SRM 51-40-3 FIG 1.