What was found
FOUND FWD CARGO COMPT FRAME AT STA 680 IS DENTED AT UPPER FLANGE BETWEEN STR 23R - 24R. CUTOUT DAMAGED AREA 3 1/2" BY 1" AT FWD CARGO STA 680 STR 23R-24R IAW SRM 51-40-3 FIG 1. FABRICATED DOUBLER WITH 7075-0 .071 SIZE 12 1/2" BY 2" PO NR 9003110 AS PER B727 SRM 53-10-2 FIG 3, SRM 51-40-3 FIG 1. HEAT TREATED TO 7075 T6 IAW FLIGHTSTAR ENGINEERING REPORT NR 2-37153-801 REV IR AND B727 SRM 51-10-3. TREATED AND PRIMED DOUBLER AS PER B727 SRM 51-10-2. INSTALLED DOUBLER AT FWD CARGO COMPT FRAME STA 680 BETWEEN STR 23R-24R AS PER B727 SRM 51-40-3 FIG 1.