What was found
FWD CARGO COMPT FRAME AT STA 700 IS DENTED IN 2 PLACES BETWEEN STR 23L-25L. CUTOUT DAMAGE AREA AT BS 700 STR 23L TO 25L 2EA DIM 1.10" BY 1" IAW SRM 53-10-1. FABRICATED FRAME REPAIR USING 7075 "0" .071 PO NR 9003189 DIM19" NR 4 1/2" IAW B727 SRM 53-10-2. HEAT TREATED PART FROM 7075 "0" T0 7075 T6 IAW FLIGHTSTAR A/C SERVICE ENGINEERING REPORT NR 2-37153-801 REV IR. ALODINE AND PRIMED PART AND AREA IAW B727 SRM 51-10-2. INSTALLED FRAME REPAIR IAW B727 SRM 51-40-3.