What was found
FOUND FUSELAGE SKIN IS PUNCTURED AT APPROX STA 700 AND STR 23L. OPENED SIDE WALL LOWER SECTION IAW B727 SRM 25-52-00. REMOVED EXISTING REPAIR IAW B727 SRM 51-30-2. CUT OUT DAMAGE AREA OF SKIN DIM 2 1/8" BY 2 IAW B727 SRM 53-30-3 FIG 3. FABBED DOUBLER USING 2024 T3 .063 PO NR 9003110 DIM 10" BY 8 1/2" AND FILLER FROM 2024 T3 .050 PO 9003002 DIM 2 1/8: BY 1" IAW B727 SRM 53-30-02 FIG 2 AND 53-30-3 FIG 3. ALODINE AND PRIMED PARTS AND AREA IAW B727 SRM 51-10-2. INSTALLED PARTS IAW B727 SRM 53-30-3 FIG 3. CLEANED AREA IAW B727 M/M 12-40-0. CLOSE SIDE WALL PANEL IAW B727 M/M 25-52-00. THIS REPAIR IS A CATEGORY "A".