What was found
FUSELAGE STR 23L CRACKED AT STA 698. CUT OUT DAMAGE STRINGER DIM 13 INCHES IAW B727 SRM 53-10-3 FIG 1. FABBED STRINGER SECTION FROM P/N BAC1498-142 7075 -T62 PO 4002741 DIM 13 INCHES AND 2EA SPLICES FROM BAC 1498-132 PO 610190 DIM 12 INCHES EA IAW B727 SRM 53-10-2 FIG 9 AND 53-10-3 FIG 1. ALODINE AND PRIMER PARTS AND AREA IAW B727 SRM 51-10-2, INSTALLED STRINGER REPAIR IAW B727 SRM 53-10-3 FIG 1.