As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FRAME DENTED AT BS 680 AT STR 24R. CUT OUT DAMAGED AREA SIZE 1 X 3/4 ON FRAME STA 680 AT STR 24R IAW B727 SRM 51-10-1. FABBED REPAIR ANGLE FROM 7075 .063 SIZE 8 3/4 X 3 1/2 PO 9002827 IAW B727 SRM 51-40-3 FIG 1 AND SRM 53-10-2 FIG 3. HEATED TO 7075 T6 .063 TREATED AND PRIMED PART AND AREA IAW B727 SRM 51-10-2. INSTALLED REPAIR PARTS IAW B727 SRM 51-40-3 FIG 1.