What was found
ACFT SUSTAINED DAMAGE ON LEFT SIDE OF NOSE AT APPROX BS 197, 8" ABOVE STR 25L. CUT OUT DAMAGED SECTION OF FUSE, 5.75" BY 2.25" AT BS 197. FABRICATED; DOUBLER FROM 2024-T3, .071" BY 11.5" BY 9.562", PO NR 9004067, AND FILLER FROM 2024-T3, .063" BY 12.5" BY 9.5", PO NR 9004099, PER B727 SRM 53-10-3 FIG 5. TREATED, PRIMED, AND INSTALLED REPAIR PARTS PER B727 SRM 51-10-2 AND 53-30-3 FIG 5.