What was found
ACFT SUSTAINED DAMAGE ON LEFT SIDE OF NOSE AT APPROX STA 230, BETWEEN STR 23L AND 25L. CUT OUT DAMAGED AREA, 6.25" BY 9.875". FABRICATED DOUBLER FROM 2024-T3, .071" BY 16.5" BY 14", PO NR 9004067, AND FILLER FROM 2024-T3, .063" BY 13.75" BY 15.5", PO NR 9004099, PER B727 SRM 53-30-3 FIG 5 AND 53-30-2 FIG 1. TREATED, PRIMED, AND INSTALLED REPAIR PARTS PER B727 SRM 53-30-5 FIG'S 5 AND 27, AND 51-10-2.