What was found
DISCREPANCY FOUND NR 110587; DENT LT SIDE FUSELAGE SKIN AT STA 373 STR. 24L (MARKED). DENT IS IN AREA NOT ALLOWED IAW SRM SPECIFICATIONS. CUT OUT DAMAGED AREA DIM 3INCHES X 1INCH FABBED FILLER 2024-T3 .050 PO 9002695 3.1 INCHES X 1.3 INCHES AND DOUBLER 2024-T3 .063 14.5 INCHES X 6.6 INCHES PO 53125 IAW SRM 53-30 3 FIG 3 TREATED AND PRIMED REPAIR IAW SRM 51-10-2 INSTALLED REPAIR PARTS IAW SRM 53-30-3 FIG 3.