What was found
FOUND NR 111053; ACCOMPLISH IDENTIFICATION OF EXISTING EXTERNAL FUSELAGE SKIN REPAIR AT BS 305 & BETWEEN STR 8L - 11L (L1 DOOR UPPER HINGE CUTOUT). ACCOMPLISHED IDENTIFCATION OF EXISTING EXTERNAL FUSELAGE SKIN REPAIR AT BS 305 BETWEEN STR 8L - 11L (L1 DOOR UPPER HINGE CUTOUT). INSTALLATION PERFORMED IAW B727 SB-53-198 REV 2. VERIFIED MAT USED IS CRES AISI 15-5 PH 0.063. THIS IS A CATEGORY B. INSP THRESHOLD 40,000 CYCLES, INTERVAL 3,000 CYCLES.