What was found
DENT IN LOWER FUSELAGE SKIN STA 350 RIGHT SIDE 6 INCHES BELOW YELLOW / RED PAINT LINE. REMOVED FASTENERS FOR ACCESS AT STA 350 RT SIDE IAW B727 SRM 51-30-1. CUT OUT DAMAGED AREA DIM 7 X 5 INCHES IAW B727 SRM 53-30-3 FIG 1A. REMOVED INTERNAL WEB PANEL FOR ACCESS IAW B727 SRM 51-30-2. FABRICATED DOUBLER REPAIR MAT USED 2024-T3 .050 PO9002827 DIM 14.5 X 13 INCHES AND 1EA FILLER MAT USED 2024-T3 .063 PO9002827 DIM 13 X 12 INCHES IAW B727 SRM 53-30-3 FIG 14 AND 53-30-2 FIG 2. TREATED AND PRIMED AREA IAW B727 SRM 51-10-2, INSTALLED REPAIR IAW B727 53-30-3 FIG 14 AND 51-30-2 FIG 2. REINSTALLED INTERNAL WEB PANEL IAW B727 SRM 51-30-2 CAT B REPAIR.