What was found
AFT CARGO COMPT CUTOUT STA 990 INNER CHORD IS CORRODED WITH EXFOLIATION ON AFT SURFACE BETWEEN STR 26R AND STR 27R. CUT OUT DAMAGE AREA AT STA 990 STR 26R TO 27R DIM .75 X .75 INCH IAW B727 SRM 51-40-4 FIG 1. FAB ANGLE REPAIR MAT USED BAC1514-1437 PO 6101107 DIM 9.5 X 3 INCH FILLER MAT USED 7075T6 .100 PO 9002955 DIM .75 X .75 IAW B727 SRM 53-10-2 FIG 5 51-40-4 FIG 1 AND 51-20-1 FIG 2. TREATED AND PRIMED PART AND AREA IAW B727 SRM 51-10-2, INSTALLED REPAIR IAW B727 SRM 51-40-4 FIG 1 AND 51-30-2 CAT B-REPAIR.