What was found
PILLOWING FASTENERS ON RIGHT FUSELAGE SKIN BS 990 STR 27R. REMOVED FLOORBOARD FROM BS 950E TO 990 IAW B727 SRM 51-30-2 FIG 15. REMOVED 3 EA FLOOR SUPPORT FOR ACCESS IAW B727 SRM 51-30-2. FOUND AREA WITH CORROSION OUT OF LIMITS IAW B727 SRM 53-30-1. CUT OUT DAMAGED AREA DIM 4.25" X 3" IAW B727 SRM 51-10-1 AND 53-30-1, FABRICATED DOUBLER USING 2024 T3 .125 PO 9003898 DIM 15.125" X 13.25" AND FILLER 2024 T3 .100 PO 9003670 DIM 4.25" X 3" IAW B727 SRM 53-30-2 FIG 3. TREATED AND PRIMED PARTS AND AREA IAW B727 SRM 51-10-2, INSTALLED REPAIR PARTS IAW B727 SRM 53-30-3 FIG 3. INSTALLED 3 EA FLOOR SUPPORTS FROM 950E TO 990 IAW B727 SRM 51-30-2. CLEANED AREA AND DINOTROLED IAW B727MM 12-40-0 AND 51-20-14, CLOSED FL