What was found
NR 6 SLAT AT ACT ROD END ATTACHMENT WS 515 HAS BOTH I/B & O/B FRAMES CRACKED FWD. REMOVED I/B & O/B NR 6 SLAT FRAMES AT WS 515 IAW B727 SRM 51-30-2, FAB NEW I/B & O/B FRAMES FROM 20024-0 .040 PO 9003230 DIM. FOR BOTH FRAMES 6 X 16 INCHES IAW B727 SRM 57-50-2 FIG 2 & SRM 51-20-1. HEAT TREATED FRAMES TO T4 CONDITION IAW B727 ENGINEERING REPORT 2-37153-801 REV IR, TREATED & PRIMED FRAMES AND WORKING AREA IAW B727 SRM 51-10-2. INSTALLED I/B & O/B FRAMES AT NR 6 SLAT WS 515 IAW B727 SRM 51-30-2.