What was found
ON ENG START - START WAS NORMAL. ENG ACCELERATED TO 30 PERCENT N1, 520 EGT 52 PERCENT N2. GRD PERSONNEL REPORTED ENG SMOKING & ENG FLAMED-OUT. ENG FAILURE CHECKLIST COMPLETE. FLOW CHART COMPLETE. INSP INLET & EXHAUST - NO DAMAGE NOTED. OPENED COWLING & INSP G/B & FCU, DRAINED WATER FROM MOISTURE TRAP. RAN ENG AT IDLE & 1.8 EPR, OPS CKD GOOD IAW JRH 5.2 & 6.2.