What was found
ASTAR NR 111384: LT IB MID FLAP T/E LOWER STRUCTURE, WBL 70 TO 134 IS CRACKED FOUR PLACES IN CUT OUTS. CUT OUT DAMAGED AREA IAW SRM 51-30-2 AND 51-40-3, FIG.1. FAB NEW FROM AC 1003-100046-7075-T6, SIZE 68.75 INCH PO NR 6295115 AND ONE SPLICE WITH AC 1003-100046-7075-T6, SIZE 9 INCH, PO NR 6295115 IAW SRM 57-50-2 AND 51-40-3, FIG.1, TREATED AND PRIMED REPAIR PARTS IAW SRM 51-10-2. INSTALLED NEW PART IAW SRM 51-30-2.