What was found
LOWER LOBE AND WALKWAY BEAM LT SIDE, BS 294, CORROSION ON CHORD. REMOVED, FAB AND REPLACED CORRODED STIFFENER FROM P/N BAC 1505-29222, PO NR 9003865, IAW SRM 51-30-2, 51-30-5, 53-10-2 FIG 1 AND 51-20-1 FIG2. CUT OUT DAMAGED WEB AND FAB DOUBLER FROM 2024-0, .040, PO NR 9003230, APPROX 4 BY 3 IAW SRM 57-40-2 FIG1 AND 53-10-2 FIG 2. HEAT TREATED REPAIR DOUBLER TO T4 CONDITION IAW ENGINEERING REPORT NR 2-37153-801 REV IR. TREATED AND PRIMED DOUBLER PART IAW SRM 51-10-2. INSTALLED REPAIR DOUBLER IAW SRM 51-40-2 FIG1 AND 51-30-2. INSTALLED LOWER WALKWAY WEB IAW SRM 51-30-2.