What was found
CABIN DOOR EMERGENCY EXIT LIGHT DOES NOT COME ON DURING STBY POWER AND BATTERY CHECK. RESEATED LIGHT, OPS CHECK GOOD PER MM 33-50-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN DOOR EMERGENCY EXIT LIGHT DOES NOT COME ON DURING STBY POWER AND BATTERY CHECK. RESEATED LIGHT, OPS CHECK GOOD PER MM 33-50-01.