What was found
LEFT WING AFT FLAP UPPER SURFACE, INBD END DELAMINATED. CUTOUT DAMAGE/DELAMINATED AREA APPROX DIM 3" BY 1". FAB FILLER APPROX 3" BY 1" AND DOUBLER APPROX 6 BY 2.5" FROM P/N 7075-T6, .012, PO NR 5397662. CLEANED, ANODIZED, PREPPED AND PRIMED AREA, FILLER AND DOUBLER FOR BONDING IAW B727 SRM 51-40-24, FIG 2 AND 51-40-20. INSTALLED REPAIR AND BONDED IAW B727 SRM 51-40-20 PARA 22, 51-40-24, FIG 2, PARA 20, FIG 12-14 AND B727 M/M 51-20-00.