What was found
TIRE DEBRIS DAMAGE ON LEFT WING INBD AFT FLAP LWR SURFACE. CUTOUT DAMAGE/DELAMINATED AREA ON LT INBD AFT FLAP LWR SURFACE APPROX DIM 13" BY 15". FAB FILLER APPROX 13" BY 15" AND DOUBLER APPROX 15" BY 16" FROM P/N 2024-T3, .016, PO NR 9003189. CLEANED, PREPPED AND PRIMED FOR BONDING. INSTALLED IAW B727 SRM 57-50-2, FIG 3, 51-41-20, FIG 12 AND 14. RESTORED FIBERGLASS PACK SHIELD AND PRIMED AREA IAW B727 SRM 51-40-19 AND B727 MM 51-20-01.