What was found
LT INBD FLAP LWR SURFACE HAS TWO CRACKS OF 0.500" AND 0.125" AT STA XW 12.000 AND XW 66.000 (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW SRM 57-7-1 FIG 1. REMOVED DAMAGED PANEL PLATING IAW SRM 57-1-0, SRM 51-1-21. FABRICATED NEW PLATING (AL 2024T3 0.032") AND BONDED FINGER DOUBLER (AL2024T3 0.020") IAW SRM 57-7-1 FIG 1 ITEM "B" "L". BONDED BOTH PARTS WITH HYSOL IAW SRM 51-1-9, SRM 51-1-9A. CLEANED, TREATED AND PRIMED AREA AND NEW PANEL PLATING IAW SRM 51-1-8B. APPLIED SEALANT TO FAYING SURFACE IAW SRM 51-1-11. INSTALLED NEW PANEL PLATING IAW SRM 51-1-21, SRM 51-3-0, SRM 51-3-1.