What was found
MAIN CARGO COMPT FLOORBEAM HOLE MISDRILLED STA 620.000 LBL 10 (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW SRM 53-2-0 FIG 1G, TR 53-124 DATED 09-30-01. REMOVED FASTENERS IAW SRM 51-1-21. FABRICATED REPAIR ANGLE AND PROTECTIVE STRAP IAW SRM 53-2-0 FIG 1G (SHEET 1-2). CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS IAW SRM 51-1-8B. APPLIED SEALANT TO FAYING SURFACES IAW SRM 51-1-11. INSTALLED REPAIR PARTS IAW SRM 53-2-0 FIG 1G SHEET 1-2, SRM 51-1-20D, SRM 51-3-1.