What was found
LT INBD FLAP FORMER 1" CRACK STA XW 122.000. REMOVED FASTENERS IAW SRM 51-1-21. PERFORMED STOP HOLE AND FABRICATED ANGLE DOUBLER IAW SRM 57-2-0 PG 9-10 (AL2024T3 0.063"). CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. INSTALLED NEW ANGLE DOUBLER IAW SRM 57-2-0 PG 9-10, SRM 51-1-21, SRM 51-3-0, SRM 51-3-1 (TORQUE).