What was found
LT INBD VANE SLOT HAS ELONGATED HOLES AT STA XILD 0.7095 (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW FAA FORM 8110-3 DATED 11-10-06, DWG AC24-57-R02 REV IR DATED 10-30-06. REMOVED FASTENERS IAW SRM 51-1-21, SRM 51-3-0. CUT OUT DAMAGED SECTION IAW DWG AC24-57-R02. PERFORMED NDT INSP IAW DC8 NDT SPM PART 06-10-01-001 (NO CRACK OR CORROSION FOUND AFTER CUT OUT). FABRICATED EXT REPAIR DOUBLER (AL7075T6 0.071") INTERNAL DOUBLER (AL7075T6 0.050") AND FILLER (AL7075T6 0.063") IAW DWG AC24-57-R02. CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS IAW SRM 51-1-8B. APPLIED SEALANT TO FAYING SURFACES IAW SRM 51-1-11. INSTALLED REPAIR PARTS IAW DWG AC24-57-R02, SRM 51-1-21, SRM 51-1-20D, SRM 51-3-1 (TORQUE).