What was found
NR 4 PYLON INBD ADAPTER PANEL 1" CRACK STA YN 323.000 LT (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW DC8 70 SB 54-93 CONDITION V. REMOVED FASTENERS FROM REPAIR AREA AND ATTACH PARTS IAW DC8 70 SB 54-93, SRM 51-1-21, SRM 51-3-0. FABRICATED DOUBLERS (4) (AL7075T6 0.090") IAW DC8 10 SB 54-93 CONDITION V FIG I SHEET 1, 3 PG 8-10. CLEANED, TREATED AND PRIMED REPAIR PARTS IAW SRM 51-1-8B. APPLIED SEALANT TO FAYING SURFACES IAW SRM 51-1-11. INSTALLED REPAIR PARTS IAW DC8 70 SB 54-93 COND V FIG I SHEET 1,3, FIG 2 SHEET 1, 2, SRM 51-1-21, SRM 51-3-0, SRM 51-3-1. FOR REMOVAL AND REINSTALLATION ACCESS DOOR AND FAIRING OF PYLON SEE JC 8-10-74-005, JC 8-70-74-005.